Firmware Updates
Last updated
Last updated
Firmware updates must be performed when a new version is released by AVSS. Check the AVSS website regularly for firmware updates, and contact AVSS customer support if you have any questions.
If a new firmware update is required, an email will be sent from the AVSS support team informing all users that an update is needed. Users can then visit the AVSS website (URL https://www.avss.co/), navigate to "Products" - "Drone Parachute Recovery Systems" and click on the relevant product page to see the updated firmware file. The file will be in a ZIP format with the version indicated in the title, as shown below:
Upon accessing and downloading the latest firmware file, users can then import the firmware update onto their PRS using the AVSS Assistant. The AVSS Assistant can be downloaded from the AVSS website (usually in a ZIP format file). The current version number of the software will be included in the file name, as shown below.
The AVSS Assistant can then be installed on a local computer by extracting the "setup.exe" file (as indicated below) and following the installation instructions (also indicated below).
Upon completing the installation, users should see the following screen when they open the AVSS Assistant. The red coloring of the charging cord in the "PRS Connect" box (at top left of screen) indicates that there is presently no PRS-M3DTEX attached to the computer. If the PRS-M3DTEX is connected via USB cord to the computer (see second image below), this icon will turn green to indicate a successful connection.
Upon a successful connection between the PRS-M3DTEX and the AVSS Assistant program, the updated firmware file can be imported into the PRS-M3DTEX by first placing the PRS-M3DTEX into "SD Mode".
Once the PRS-M3DTEX is placed into "SD Mode", the PRS-M3DTEX should automatically disconnect from the local computer, which is indicated to the user with a dialog box.
When in "SD Mode", the PRS-M3DTEX acts as a standard USB device, where its file directory is visible as an external connection to the local computer.
To apply the firmware update, simply navigate to the .sfb files (located within the updated firmware's ZIP file) and copy/paste these files into the PRS-M3DTEX's main directory.
Upon pasting the firmware update into the PRS-M3DTEX's main directory, the user should close the SD card directory window and then cycle the PRS-M3DTEX's power by unplugging the PRS-M3DTEX from the computer and then re-plugging it in.
ENSURE THAT THE PRS-M3DTEX'S SD CARD DIRECTORY WINDOW IS CLOSED PRIOR TO DISCONNECTING THE PRS-M3DTEX FROM THE COMPUTER TO AVOID CORRUPTING THE PRS-M3DTEX SD CARD.
The PRS-M3DTEX will then update the firmware accordingly, which is indicated to the user by the PRS-M3DTEX's status LED displaying as white.
DO NOT DISCONNECT THE PRS-M3DTEX FROM THE LAPTOP WHILE THE STATUS LIGHT IS WHITE, AS THIS WILL PREVENT THE UPDATE FROM COMPLETING SUCCESSFULLY.
Upon successful completion of the firmware update, the PRS-M3DTEX status light will change from white to green. Leave the PRS-M3DTEX connected to the computer and navigate to the "Device Information" tab in AVSS Assistant to verify the current firmware version.