Operating Procedures
1. Installation Checklist
2. Pre-Flight FTS Check
The PRS-M3DTEX performs an automatic pre-flight FTS diagnostic check on each startup of the system
The diagnostic verifies that the FTS functionality is operational without shutting down the drone.
If the diagnostic fails, the PRS will send a "WARNING: EFTS Diagnose Failed" message to the DJI transmitter and/or Flight Hub 2 PSDK Window.
If the diagnostic passes, there will no messages about the Diagnostic.
3. Pre-Flight Checklist
AUTO-TRIGGER WILL ONLY ARM ONCE AN ALTITUDE OF 34 METERS (111.15 FT) IS REACHED. VERIFY THE ARM STATUS ON THE PSDK TEXT WINDOW [ARMED: ATS, GEOFENCE].
MANUAL TRIGGER DEVICE CAN ONLY BE ARMED ONCE AN ALTITUDE OF 5 METRES (16.4 FT) IS REACHED
4. In-Flight Checklist
THE MINIMUM DEPLOYABLE ALTITUDE FOR THE PRS-M3DTEX IS 34.8 METERS. WHEN OPERATING OVER PEOPLE, DO NOT FLY BELOW THE 34.8 METERS (114.17 FEET). IF THE PRS IS DEPLOYED BELOW THE MDA, AVSS DOES NOT WARRANT THE PRS WILL PERFORM AS INTENDED.
5. Landing Checklist
ENSURE THE PRS-M3DTEX LED IS OFF BEFORE HANDLING THE DJI M3D/T.
6. Post-Flight Checklist (No Deployment)
7. Deployment Checklist
8. Post-Flight Checklist (With Deployment)
Last updated