Operating Procedures

1. Installation Checklist

2. Pre-Flight FTS Check

  • The PRS-M3DTEX performs an automatic pre-flight FTS diagnostic check on each startup of the system

  • The diagnostic verifies that the FTS functionality is operational without shutting down the drone.

  • If the diagnostic fails, the PRS will send a "WARNING: EFTS Diagnose Failed" message to the DJI transmitter and/or Flight Hub 2 PSDK Window.

  • If the diagnostic passes, there will no messages about the Diagnostic.

3. Pre-Flight Checklist

DO NOT HANDLE OR MOVE THE DJI M3D/T ONCE THE PRS-M3DTEX IS TURNED ON UNLESS CALIBRATING EITHER THE PRS-M3DTEX IMU OR THE DJI M3D/T COMPASS. REFER TO THE "CALIBRATION PROCESSES" SECTION FOR INSTRUCTIONS ON HOW TO CALIBRATE EACH OF THESE COMPONENTS.

AUTO-TRIGGER WILL ONLY ARM ONCE AN ALTITUDE OF 34 METERS (111.15 FT) IS REACHED.

MANUAL TRIGGER DEVICE CAN ONLY BE ARMED ONCE AN ALTITUDE OF 5 METRES (16.4 FT) IS REACHED

4. In-Flight Checklist

THE MINIMUM DEPLOYABLE ALTITUDE FOR THE PRS-M3DTEX IS 34.8 METERS. WHEN OPERATING OVER PEOPLE, DO NOT FLY BELOW THE 34.8 METERS (114.17 FEET).

5. Landing Checklist

ENSURE THE PRS-M3DTEX LED IS OFF BEFORE HANDLING THE DJI M3D/T.

6. Post-Flight Checklist (No Deployment)

7. Deployment Checklist

8. Post-Flight Checklist (With Deployment)

Last updated